TeleBeacon Telemetry
Applications
TeleBeacon Interfaces -
Onboard
The
following external (physical) interfaces are available onboard the standard
TeleBeacon:
• 1 x Presentation Port,
RS232, 38400, N,8,1, no-flow control;
• 1 x Auxiliary Port, RS232, 1200, 2400,
4800, 9600, 19200 or 38400, N,8,1, no-flow control (Baud rate user selectable);
• 4 x Telemetry Analogue Inputs (A1, A2,
A3, A4)
• 4 x Telemetry Status Inputs/Outputs (A1,
S2, S3, S4)
• 1 x GPS 1pps / Off Position Indicator
Summary – TeleBeacon
Telemetry Analogue and Status Characteristics
|
Telemetry
Channel
|
I/O Type
|
AtoN Status Bit No.
|
Analogue / Status Value
|
AtoN Status Bits - Event Manager options
per channel
|
Voltage Range
|
Channel Functional Description
|
|
A1
|
Input
|
0
|
0
to
1023
|
1. Voltage greater than
X
2. Voltage less than X
3. Voltage between X &
Y
4. Voltage outside X &
Y
|
0 – X
Volt
|
User
assigned
|
|
A2
|
1
|
|
A3
|
2
|
|
A4
|
3
|
|
S1
|
I/O
|
4
|
0 or 1
|
High
(1) or Low (0)
|
0, X
Volt
|
|
S2
|
5
|
|
S3
|
6
|
|
S4
|
7
|
|
GPS
1pps
or
Off
Position Indicator
|
Output
|
Not
applicable
|
User
selected
$GPRMC
output on Aux. Port used with GPS 1pps
|
• Analogue resolution is a 10 bit value,
range 0 to 1023.
• Voltage input range is 0 to X Volts (X
usually not > 20V, but not necessary restricted).
• Each channel can have a different input
voltage range, depending on the third-party interface
equipment (viz. LED
Flasher, Battery, Solar Panel, Tidal height
measuring instrument, etc.)
• Each analogue channel’s voltage range is
determined at pre-installation / installation time.
Message Type and
Interface Summary
The
TeleBeacon AIS VDL messages that include telemetry encapsulated custom data
comply with the respective International Standard formats.
Messages
and information below illustrate some of the TeleBeacon Telemetry applications.
1. TeleBeacon Message
Formats – Custom Data
1.1 AtoN Status (8 bits) - Message 21
1.2 TeleBeacon Telemetry - Message 6
!AIVDM,1,1,,B,62wO@cT005RpvNL02OVvWqg`Mh0,2*56
View
Message Filter Image
1.3 Sealite LED Flasher SL125 - Message 6
!AIVDM,2,1,0,B,62wJDAP005RpwsqCC2hh=jhh>2i1;30n=CHm=jhj=CDh;SPh<3DdDjhh
!AIVDM,2,2,0,B,=2pq=k4p;4D,2*40
View Message Filter Image
1.4 Aanderaa Dataloggers 3660 & 3634 –
Message 6
1.4.1 Last Reading
– Channels 00 - 08
!AIVDM,2,1,3,B,60C921h005RpvOd105@j411D<5@j441D
!AIVDM,2,2,3,B,E38@,0*18
View
Message Filter Image
1.4.2 Last Reading
– Channels 09 - 17
!AIVDM,2,1,4,B,60C921l005RpvOd2T5@j405D
!AIVDM,2,2,4,B,E38@,0*1F
View Message Filter Image
1.4.3 Simple Printout – Channels 00 - 17
!AIVDM,2,1,8,B,60C921p005RpvOd3004@0B01<0500E01H05h0H01T0410A418@4i0D41D@5Q,0*6F
!AIVDM,2,2,8,B,0G41,0*6F
View
Message Filter Image
2. TeleBeacon
Message – Standard Formats
2.1 AtoN Status ( 8 bits) - Message 21 - IALA
Defined Regional Bits - Page ID 7
2.2 Message 6 & 8 - International Function
Messages (IFM 0)
2.2.1 IFM 0 – COG, SOG
Message
21 does not support COG and SOG parameters.
Internal
GPS COG and SOG data is used for this message.
!AIVDM,1,1,,B,62wJDAd005Rp04000??GU?2s00,4*36
View Message Filter Image
!AIVDM,1,1,,B,82wJDAP0@000uLcTt;d0,0*12
View
Message Filter Image
2.2.2 IFM 0 – Free Text (e.g. “OIL SPIL CLEANUP OPERATION IN
PROCESS – STAY CLEAR”)
!AIVDM,1,1,,A,62wJDAP005Rp04000tTj1=0Tj18D2n1=@5V0
View Message Filter Image
!AIVDM,1,1,,A,82wJDAP0@003jC84l2C84Q@kmQDVH2C`44SilQDp;H4m0FH0k1@DP0,4*13
View
Message Filter Image
2.3 Message 8 – Meteorological and Hydrological
Data (IMO SN/Circ. 236)
!AIVDM,1,1,,B,80C921h0@vQO4hkcFQWfv?5WdrF<0,2*3B
View
Message Filter Image
3. TeleBeacon Utility Software – Configure
TeleBeacon Profile
4. More TeleBeacon Integrations (more information available on request)
LMVSA
DES33
Omex TidaLite
IV
Sabik SmartFlasher
Sabik LEDFlasher
Tideland (general failure)