TeleBeacon Telemetry Applications

TeleBeacon Interfaces - Onboard

The following external (physical) interfaces are available onboard the standard TeleBeacon:

        1 x Presentation Port , RS232, 38400, N,8,1, no-flow control;

        1 x Auxiliary Port, RS232, 1200, 2400, 4800, 9600, 19200 or 38400, N,8,1, no-flow control (Baud rate user selectable);

        4 x Telemetry Analogue Inputs (A1, A2, A3, A4)

        4 x Telemetry Status Inputs/Outputs (A1, S2, S3, S4)

        1 x GPS 1pps / Off Position Indicator

Summary – TeleBeacon Telemetry Analogue and Status Characteristics 

Telemetry

Channel

I/O Type

AtoN Status Bit No.

Analogue / Status Value

AtoN Status Bits - Event Manager options per channel

Voltage Range

Channel Functional Description

A1

Input

0

0

 

to

 

1023

1. Voltage greater than X

2. Voltage less than X

3. Voltage between X & Y

4. Voltage outside X & Y

0 – X Volt

User assigned

A2

1

A3

2

A4

3

S1

I/O

4

0 or 1

High (1) or Low (0)

0, X Volt

S2

5

S3

6

S4

7

GPS 1pps

or

Off Position Indicator

Output

Not applicable

User selected

$GPRMC output on Aux. Port used with GPS 1pps


        Analogue resolution is a 10 bit value, range 0 to 1023.

        Voltage input range is 0 to X Volts (X usually not > 20V, but not necessary restricted).

        Each channel can have a different input voltage range, depending on the third-party interface

         equipment (viz. LED Flasher, Battery , Solar Panel, Tidal height measuring instrument, etc.)

        Each analogue channel’s voltage range is determined at pre-installation / installation time.

Message Type and Interface Summary

The TeleBeacon AIS VDL messages that include telemetry encapsulated custom data comply with the respective International Standard formats.

Messages and information below illustrate some of the TeleBeacon Telemetry applications.

1. TeleBeacon Message Formats – Custom Data

1.1  AtoN Status (8 bits) - Message 21

msg21.jpg  

1.2  TeleBeacon Telemetry - Message 6

!AIVDM,1,1,,B,62wO@cT005RpvNL02OVvWqg`Mh0,2*56

View Message Filter Image

1.3  Sealite LED Flasher SL125 - Message 6

!AIVDM,2,1,0,B,62wJDAP005RpwsqCC2hh=jhh>2i1;30n=CHm=jhj=CDh;SPh<3DdDjhh
!AIVDM,2,2,0,B,=2pq=k4p;4D,2*40

View Message Filter Image

1.4  Aanderaa Dataloggers 3660 & 3634 – Message 6

1.4.1  Last Reading – Channels 00 - 08

!AIVDM,2,1,3,B,60C921h005RpvOd105@j411D <5@j441D
!AIVDM,2,2,3,B,E38@,0*18

View Message Filter Image

1.4.2  Last Reading – Channels 09 - 17

!AIVDM,2,1,4,B,60C921l005RpvOd2T5@j405D
!AIVDM,2,2,4,B,E38@,0*1F

View Message Filter Image

1.4.3  Simple Printout – Channels 00 - 17

!AIVDM,2,1,8,B,60C921p005RpvOd3004@0B01<0500E01H05h0H01T0410A418@4i0D41D@5Q,0*6F
!AIVDM,2,2,8,B,0G41,0*6F

View Message Filter Image

2.  TeleBeacon  Message – Standard Formats

2.1  AtoN Status ( 8 bits) - Message 21 - IALA Defined Regional Bits - Page ID 7

msg21pg7.jpg

2.2   Message 6 & 8 - International Function Messages (IFM 0)

2.2.1  IFM 0 – COG, SOG

Message 21 does not support COG and SOG parameters.
Internal GPS COG and SOG data is used for this message.

!AIVDM,1,1,,B,62wJDAd005Rp04000??GU?2s00,4*36

View Message Filter Image

!AIVDM,1,1,,B,82wJDAP0@000uLcTt;d0,0*12

View Message Filter Image

2.2.2  IFM 0 – Free Text (e.g. “OIL SPIL CLEANUP OPERATION IN PROCESS – STAY CLEAR”)

!AIVDM,1,1,,A,62wJDAP005Rp04000tTj1=0Tj18D 2n1=@5V0

View Message Filter Image

!AIVDM,1,1,,A,82wJDAP0@003jC84l2C84Q@kmQDVH2C`44SilQDp;H4m0FH0k1@DP0,4*13

View Message Filter Image

2.3  Message 8 – Meteorological and Hydrological Data (IMO SN/Circ. 236)

!AIVDM,1,1,,B,80C921h0@vQO4hkcFQWfv?5WdrF <0,2*3B

View Message Filter Image

3.  TeleBeacon Utility Software – Configure TeleBeacon Profile

tbsop.jpg


4.  More TeleBeacon Integrations (more information available on request)

    LMVSA DES33
    Omex TidaLite IV
    Sabik  SmartFlasher

     Sabik LEDFlasher
    Tideland (general failure)

  download.jpg Download

 

 

 

 

 

http://maritec.co.za/index.php?pr=Telemetry

http://maritec.co.za/index.php?pr=History

http://maritec.co.za/index.php?pr=AIS_Overview

http://maritec.co.za/index.php?pr=Products

http://maritec.co.za/index.php?pr=ADS

http://maritec.co.za/index.php?pr=AIS_Track_Lite

http://maritec.co.za/index.php?pr=APIRB

http://maritec.co.za/index.php?pr=PMG1

http://maritec.co.za/index.php?pr=TeleBeacon_Type1

http://maritec.co.za/index.php?pr=TeleBeacon_Type2

http://maritec.co.za/index.php?pr=Telemetry

http://maritec.co.za/index.php?pr=Downloads

http://maritec.co.za/index.php?pr=FAQ

http://maritec.co.za/index.php?pr=News

http://maritec.co.za/index.php?pr=Contact_Us

http://maritec.co.za/index.php?pr=Links

http://maritec.co.za/index.php?pr=Disclaimer

http://maritec.co.za/index.php?pr=Warranty

http://maritec.co.za/index.php?pr=Sitemap

http://maritec.co.za/index.htm

http://maritec.co.za/History.htm

http://maritec.co.za/AIS_Overview.htm

http://maritec.co.za/Products.htm

http://maritec.co.za/ADS.htm

http://maritec.co.za/AIS_Track_Lite

http://maritec.co.za/APIRB.htm

http://maritec.co.za/PMG1.htm

http://maritec.co.za/TeleBeacon_Type1.htm

http://maritec.co.za/TeleBeacon_Type2.htm

http://maritec.co.za/Telemetry.htm

http://maritec.co.za/Downloads.htm

http://maritec.co.za/FAQ.htm

http://maritec.co.za/News.htm

http://maritec.co.za/Contact_Us.htm

http://maritec.co.za/Links.htm

http://maritec.co.za/Disclaimer.htm

http://maritec.co.za/Warranty.htm

http://maritec.co.za/Sitemap.htm